Fan overview
High pressure blower is made of aluminum alloy material with high performance, energy saving and low noise. It has the advantages of high wind pressure, high efficiency, high energy consumption, stable operation and long service life.
High pressure blower shell adopts advanced technology of high precision NC equipment mold processing, to ensure that the fan product technology and product quality.
Industrial fan is widely used in industrial machinery, agricultural machinery, power machinery, vacuum machinery, packaging machinery, pharmaceutical machinery, gas ventilation and fire of high temperature flue gas engineering, sewage aeration treatment engineering, environmental engineering, environmental engineering, tunnel, underground garage, senior civil building, metallurgy, mines and other places.
First, use
Flammable and poisonous gas and dust transport, coal mine ground used explosion-proof high-pressure blower, is currently in the domestic leading level of the latest energy-saving main fan, it can be applied to coal and metal ore, ore, chemical, civil air defense engineering tunnel ventilation, also can be widely used in metallurgy, chemical, textile, building materials, etc. the industry of ventilation, transportation and purification.
1, the structural characteristics of the fan:
(1) high pressure fan has the following characteristics:
A, with the dual function of blowing and suction, a machine dual-use, you can use suction, you can also use hair dryer;
B, oil or oil free operation, the output of the air is clean;
C, relative to the centrifugal fan and medium pressure fan, the pressure is high, often more than 10 times more than the centrifugal fan;
D, if the pump body is integrally cast, and the use of the earthquake to install the feet, then it is the basis of the requirements of the installation is very low, even without a fixed foot seat can be a normal operation, very convenient, also very save installation cost and the installation period;
E, compared with the operation of the fan, low noise, ultra quiet high pressure fan:
F, maintenance free use; its loss is only two bearings, within the warranty period, basically do not need maintenance;
H, high pressure blower mechanical wear is very small, because in addition to the bearing, no mechanical contact, so the other life, of course is very long, as long as it is in normal use conditions, 3~7 is no problem..
Parke (2), wind fan special matching high quality fan vibration proof motor, the electric motor is arranged in the cavity has a certain pressure, the motor and the mine gas flow separation, flow separation chamber is provided with a ventilation duct automatically and the atmosphere, easy heat dissipation and diversion. The utility model not only increases the explosion-proof performance of the motor, but also is favorable to the heat dissipation of the motor, thereby increasing the safety of the operation of the fan.
(3) the rotating part of the fan impeller is provided with a copper device which is used for preventing friction sparks, so as to avoid the occurrence of sparks in the high-speed rotation of the cylinder and the collision of the cylinder wall.
(4) the temperature measuring element is embedded between the bearing and the stator winding of the motor, which can display the temperature of each part in the running of the fan.
2, fan performance characteristics
- flow up to 90m3/min
Vacuum up to: 100KPA
- pressure up to: 74kpa
High reliability
Cast aluminum alloy impeller and high strength shell
Simple structure, only 5 main parts - base, shell, impeller, bearing, motor
- sealed bearings to prevent contamination damage
There is only one annular chamber unit to prevent thermal stress damage
Double Chen type elastic shaft seal to reduce leakage
Full impeller support to prevent blade breakage and fan damage
- side seal clearance to reduce blower failure during high temperature operation
Oil free transportation
- hydrocarbon free, absolute no oil air supply
- to meet the requirements of health care and scientific applications
Low noise and low temperature rise
Single vortex single suction impeller design, than the "paddle wheel" design noise is low, Wen Shengxiao
- the unique design of the annular chamber, so that the flow of gas to maintain a smooth laminar flow, air flow noise
Aluminum alloy shell, good heat dissipation
3, fan special parts
(1) silencer [3]
This series is designed for silencer silencer fan special, using the dual and silencing wall composite structure, the silencing technology is the leading domestic and the application to the noise reduction effect in practice significantly, solve the problem of high pressure fan outlet noise, so as to ensure that the users have a good environment. In the design, the performance of the fan is fully considered, the internal structure of the muffler is optimized, and the resistance loss is reduced to a minimum.
Four, fan installation, commissioning
1, according to the specifications of the fan handle installation site, to ensure that the site has enough space, so that the extraction of wind energy into the atmosphere smoothly (harmful gases can not be directly discharged into the atmosphere). The base surface must be leveled, and laid a good rail.
2, the fan should be installed in the air shaft of coal mine wind with exports, and ensure the diaphragm cavity ventilation pipe through the atmosphere, embedded parts to fix the roadway and roadway joint is arranged in the negative machine joints, does not allow the fan and the air return wellhead wellhead direct docking, must install the explosion-proof door.
3, before installation, must be checked on the wind turbine components: A, B, parts are complete; the impeller rotation is flexible; C, blade and the cylinder wall is friction; D, blades are solid; E, leaves without damage. Find problems to deal with in a timely manner, never allow the existence of hidden dangers.
4, installation, each part of the blower in order to lift paved rail, where pad needs good sealing ring, bolt components will be firmly connected, according to the instructions on the use of motor connected power line and line temperature measuring instrument.
5, check whether the oil into the channel, and inject two molybdenum disulfide lithium based lubricant (or better quality grease).
6, check the parts, the correct installation of the manual brake is correct, you can try running.
7, after long distance transmission or long-term use of the motor, in use must be measured before the stator insulation resistance (insulation resistance shall not be less than 0.5 light ou 380V), after passing the examination can be connected to the power supply, start the fan. Frequently observe the current, voltage, stator and bearing temperature.
Five, fan operation and maintenance
1, before the start of the fan, we must check whether there is foreign body in the flow channel, in order to prevent the start, the fan impeller is foreign body collision, damage.
2, the fan before the start, please read the manual start, motor instructions, according to the requirements of equipment and operation started, according to the first level, after two grade sequence start fan, adjust the direction of rotation, to ensure the normal operation of the fan.
3, the blower is started, and achieve normal operation to timely observation: whether the current a, the motor exceeds the rated current; B, the fan flow is abnormal sound, timely stop check, to find out the reason, after troubleshooting, may enter the normal operation state.
In 4, the fan is equipped with fully automated production lines in use process, should have the operation records system to the fan running records, including: A, fan start and stop time, stop reason; B, environmental temperature, temperature and atmospheric pressure; C motor, working voltage, working current, all the temperature of the bearing and motor stator temperature. There were more than indicators of the project to immediately stop check; D, fan motor, air pressure and quantity; e bearing time, quantity and grade for molybdenum disulfide lithium based lubricant; abnormal F, regularly check the details; G, failure and exclusion situation.
5, when the need for anti wind, power off and brake hand brake. Brake to slow force, not a hard brake death, such as the impeller can be reversed after the rotation, otherwise it is possible to burn electrical equipment.
6, fan in the operation process, according to the manual maintenance of motor motor manufacturers, adding MoS2 lubricant grease.
7, the fan stops regularly to check whether the components meet the requirements:
A, check the motor before and after bearing. To find the problem to replace the bearing according to the model, and replace the molybdenum disulfide lithium base lubricating oil.
B, check whether the blade is loose, the blade installation angle is the same as the original set. Find problems to be dealt with in a timely manner.
Note: after the blade is adjusted, it is necessary to check whether the installation angle of each blade is the same.
8, to check the reliability of measuring instruments in order to prevent the occurrence of accidents such as thermometer, ammeter, etc..
9, drivers and other personnel often check, once the abnormal sound or vibration, heat and other phenomena, should immediately stop processing, troubleshooting can start after this.
Three, working principle
When the impeller rotates, the centrifugal force causes the air to move forward and forward to form a series of spiral motion. The impeller blades of air between the spiral spin up and the gas outside the pump body into (suction by the suction side) tank, when it enters the side channel, the gas is compressed, and then return to the impeller blade again accelerated rotation. When the air along a spiral path through the impeller and the side slot, each blade increases the degree of compression and acceleration, with rotation of the gas kinetic energy increase, so that the gas pressure through the channel along the side of a further increase. When the air reaches the connecting point of the side slot and the discharge flange (the side channel narrows at the outlet), the gas is extruded and the pump body is discharged through the outlet silencer 4.
First, characteristics
Under normal circumstances, the high-pressure blower has the following characteristics:
1, with double suction function, a dual-purpose machine, can use suction, can also be used with a high pressure blower blowing; the wind Parke 4HB series, you can also use air suction and air blowing, the equivalent of rotary vane vacuum pump the same function;
2, less oil or oil free operation, the output of the air is clean;
3, relative to the centrifugal fan and medium pressure fan, the pressure is high, often more than 10 times more than the centrifugal fan, the current maximum pressure up to 104KPA;
4, if the pump body is integrally cast, and the use of the earthquake to install the feet, then it is the basis of the requirements of the installation is very low, even without a fixed foot seat can be a normal operation, very convenient, also very save installation cost and the installation period;
5, relative to other types of fan, such as Gao Rui fan, its operation low noise, power is more obvious, more than 5.5KW will be displayed;
6, maintenance free use; its loss is only two bearings, in the warranty period, basically do not need maintenance;
7, high pressure blower mechanical wear is very small, because in addition to the bearing, no mechanical contact, so the other life, of course is very long, as long as it is in normal use conditions, 3 to 5 years is no problem. This is also the current domestic high pressure fan is the biggest reason for popularity.
High pressure vortex fan, vortex high pressure fan:
The high pressure fan operation, the current consumption of the motor increases with the increase of vacuum and pressure, such as excessive currents cause tripping, to prevent tripping or power, please as soon as possible to increase the outlet of the cross-sectional area, or is installed in the suction and exhaust side pressure air flow control valve.
A. air supply - filter should be installed at the entrance
1, the total cross-sectional area of the outlet should be greater than 1/2 of the cross-sectional area of the fan outlet.
2 as for the water supplying, the water pressure should be marked by the maximum static pressure value in the following 70% catalog.
3 in the compression aspirated, outlet temperature due to air friction is greater than 10 DEG C at room temperature is normal, it should use the pipe above 1M.
B. air suction - a muffler can be installed at the exit
The total cross-sectional area of the suction hole should be greater than 1/2 of the inlet cross section.
Wind Parke fan is a professional manufacturer of vortex blower, high pressure blower, high pressure fan, through the type of blower, industrial vacuum cleaner, blower. Dust collector, dust collector, industrial dust collector and dust removal system. Ring high pressure blower, through the multi - stage fan, such as all kinds of medium and low pressure fans, vacuum cleaners, and so on for the industrial sector
Two, use and scope of application:
The wind Parke fan is widely used in environmental engineering, industrial machinery, plastic machinery, printing machinery (dryer) (screen printing machine), photoengraving, PCB equipment, electrical equipment, medical equipment, environmental protection industry, all kinds of combustion machine, cutting machine, burning oxygen machine, cigarette filter tip molding machine, electroplating bath mixing, spray dryers, water aeration, aquaculture, screen printing machine, plate making machine, injection molding machine, automatic feeding drying machine, liquid filling machine, powder filling machine, electric welding equipment, film machinery, paper, washing clothes, carrying dry cleaning purposes, air cleaning, dry bottles, gas transmission, feeding the collection, water treatment, central dust protection, aquaculture, screen printing, electroplating, dust, food, packaging, filling, glass products, air transportation industry etc..
To buy wind Parke fan please click: wind fan http://www.597ly.cn/ fixed Tel: 86-021-67620386